docs: verify authorization deadline recovery and staggered closes

Record the 30-second grace and jitter formula, five-second sweep granularity, and isolated writer-stall rehearsal. Include server cancellation, acquisition timeout, and pool/session recovery evidence.

Co-authored-by: Honor <e0bf479eeebe47dde1e35705212a4df70616a7bc834d907ddfb18cf0405f8b1b@seiler-test.communities.public.builderlabstaging.xyz>
Signed-off-by: Brad Seiler <seiler@squareup.com>
This commit is contained in:
Brad Seiler
2026-11-04 16:32:00 -05:00
committed by GitHub
parent efdf6baaa5
commit 5b10c52f16

View File

@@ -199,6 +199,20 @@ cross the community boundary.
6. Database failure/grace tests also belong in isolated rehearsal unless the
owner authorizes a scoped fault. Record which guarantee is source-tested,
runtime-tested, or unverified; do not infer cross-pod guarantees from a local close.
The proposed worker uses a 5-second base grace plus a stable per-socket offset
below 9 seconds, evaluated on the 5-second scan cadence. Expect outage closes
across two or three sweeps, not a continuous spread; a 6–10-second blip can
close some sockets earlier than the former 10-second grace. The conservative
bound remains 30 seconds: 5 grace + 9 jitter + 5 cadence + 2×5 scan + 1 query.
Confirmed authoritative denials still close immediately.
7. For a local isolated writer-stall rehearsal, hold a users-table lock on a
separate connection. Verify the server cancels batch statements within the
900 ms cap (or a tighter operator cap), writer pool slots recover after both
timeout and task cancellation, and subsequent writes retain the writer's
original statement timeout. Release the lock and verify successful recovery.
Count `query_timeout`, `statement_cancelled`, and `pool_timeout` batch outcomes, along
with writer pool in-use/idle and fail-closed sessions per scan. A cancellation
error alone does not prove that the backend or pool slot was released.
Removal/re-addition and unban use the authoritative state at revalidation. A
transient removal restored before a scan need not disconnect an existing