Atish Patel 1cf841af13 fix: report agent usage per provider round, not once per turn
buzz-agent emitted its `usage_update` notification in exactly one place:
after `ctx.run()` returned. Until then a turn's token counters lived only
in the prompt task's stack frame. A turn that was killed mid-flight
therefore reported nothing at all — the provider had already billed every
round it completed, and no consumer ever saw any of it.

That is not a corner case for anything that terminates a turn on a clock.
Measured on a long-horizon benchmark run that relaunches its agent between
phases, 97% of the recorded usage rows came back all zeros, and the run's
recorded cost was $79.23 against the $485 the provider's own ledger billed
for the same model over the same window — a 5.9x undercount, concentrated
on the seat being relaunched. Nothing was truncated after the fact; the
tokens were never captured in the first place.

The run loop now emits a session-cumulative `usage_update` after every
usage-bearing provider response, so an interrupted turn has reported
everything but its single in-flight request. Emitting more than once per
turn is already part of the contract — buzz-acp's UsageTracker advances its
committed baseline only at publish time, and goose behaves the same way,
which is why the tracker was written to tolerate it.

The turn-start session baseline is snapshotted into RunCtx so the mid-turn
figure stays session-cumulative rather than turn-local; a turn-local number
would be discarded by a high-water-mark consumer and lose the turn
entirely. It is taken by value rather than as a handle because the loop
reports once per round, and taking the sessions lock on each of those would
serialise concurrent sessions behind one another's provider round-trips.
Both call sites now build the payload through one helper so their wire
shapes cannot drift — a divergence there would present as tokens silently
vanishing, which is the failure this reporting exists to prevent.

A SIGTERM handler was the obvious shape and does not work: at signal time
the counters are not anywhere a handler could reach. Making usage durable
during the turn is what fixes it.